Balboa Heater - M7 - 3.0kW
Works with GS/GL Balboa Spa Packs
A very common hot tub heater assembly for the plastic GS/GL spa packs by Balboa.
Fitted with 24" M7 sensor technology to regulate spa water flow and temperature (Click HERE for Details)
Solvent weld sockets for 2.0" pipe. Fixed into place with 2 x mounting studs top and bottom.
The heater is the same as 55626, but the heater element is incoloy.
The heater also comes complete with two M7 sensors, pre mounted at each end of the heater tube ready for connection to the control box. These sensors monitor each other using the onboard software to regulate the spas functions of water flow and temperature. This technology allows for a correct operating environment for the heater. The sensors automatically adapt to the flow direction and detect restrictions including dirty filters.
This Balboa heater assembly is quick to install and allows for easy servicing and troubleshooting, due to the split 2 inch buttress thread unions with O ring. The union is ready to accept glued 2 inch pipework.
3KW Version
Always match the heater number to ensure the correct specification, the 3kw can be used with GS500, 500Z, 501, 501Z (3.0KW only), 501SZ, 510, 510S, 510Z, 510SZ, 511SZ, 523DZ, GL2000 mach 3, GL2001 mach 3 systems, it is used in spa including Spaform, Hydrospa, Canadian, Aegean, Catalina, Hydropool, , Marquis Spa, , Leisurite, Leisure Bay, Signature Spas, Hot Tubs Direct.
Note:
Always use an appropriate spanner or long nose pliers to hold the terminal base before tightening or loosening the 10mm terminal nuts.
Type | Flow Thru |
MPN | 58300 |
Element | Incoloy |
Integrated in Spa Pack | Yes |
Sensor Type(s) | M7 - Probe |
Mount Type | Cilp |
Length (includes tails) | 495 mm |
Plumbing Connection | 2.0'' |
Power | 3.0 kW |
Voltage / Hz | 230V - 50/60Hz |
Amps | 11.5-12.0 |
Element Type | Incoloy |
Element Length | 10" (255mm) |
Terminal Spacing | 31.75 mm |
Compatible Spa Pack | Balboa BP |
Important Information:
Our range of Spa Packs must be installed by a competent individual or tradesman, that is trained within the industry. Spa Packs and other computerised equipment are exempt from our returns policy if they have been opened or installed. If the spa pack is suspected as being faulty, it will need to be returned to us within the warranty period and will then be forwarded to the manufacturer for inspection. If deemed to be faulty, we will replace under warranty. If the board is not at fault or is found to have been damaged due to installation, an additional charge will be required to cover the costs of shipping and return.
*Please ensure this is the correct Spa Pack as this item is non-refundable - If you are unsure, please contact our friendly customer service team for advise & support